The QE-HVPS-5K2M-P is a programmable DC high-voltage power supply providing a continuous 0 to +5 kV output with a maximum continuous load current of 2 mA. The unit is designed around an analog programming and monitoring interface, with dedicated voltage and current monitor outputs and hardware interlock inputs for system-level protection.


Design Intent - The architecture emphasizes stable high-voltage generation, low output ripple, analog programmability, measurement feedback, and protection against output fault events. Values below are taken from the current QUTE engineering datasheet supplied for this product.

Specifications are the design specifications of the model QE-HVPS-5K2M-P. Always connect the earth terminal before use, and operate this high voltage equipment only with trained personnel.
Electrical Specifications
SN | Parameter | Specification |
|---|---|---|
1 | Primary input voltage | +24 VDC ±10%; <1 A total operational current draw |
2 | Rated output voltage range | 0 to +5 kV DC; continuous programmable range |
3 | Rated output current ceiling | Maximum 2 mA total loop continuous tracking load |
4 | Output voltage polarity | Positive (+ve) configuration |
5 | Analog output programming loop | 0 to +10 V control input for 0% to 100% output scaling; ±2%; Zᵢₙ = 200 kΩ |
6 | Voltage monitoring interface | 0 to +10 V output; ±2% for 0% to 100% full-scale feedback; Zₒᵤₜ = 10 kΩ |
7 | Precision current monitoring | 0 to +10 V output; ±2%; offset ±0.1% of FS; 0% to 100% tracking; Zₒᵤₜ = 10 kΩ |
8 | Input line regulation margin | <10 ppm response change per 1 V change in primary source input |
9 | Dynamic load regulation margin | <10 ppm response stabilization from 100 µA current draw up to maximum capacity |
10 | System output drift window | After 1 h warm-up: <0.01% drift/hour; <0.05% combined drift over continuous 8 h |
11 | Hardware output protection | Dynamic intermittent-arcing suppression circuit and short-circuit-to-ground safe trip |
12 | Output ripple profile (full load) | <20 mV peak-to-peak |
13 | Temperature coefficient | <25 ppm/°C |
14 | Enclosure dimensions | 147 mm (W) × 98 mm (L) × 47 mm (H) |
15 | Total hardware unit mass | ≤1.0 kg |
16 | Input & control connector | Integrated 10-way heavy-gauge Molex friction-lock header |
17 | High-voltage output | 1 m double-shielded, screened coaxial high-insulation cable assembly |
Functional Features
Continuous analog programming from 0 to +5 kV using a 0–10 V control input.
Dedicated voltage and current monitor outputs for closed-loop system measurement and telemetry.
Hardware interlock inputs for fast response to arc / short-circuit fault conditions.
Positive output polarity configuration as specified for QE-HVPS-5K2M-P.
High-stability output architecture intended for precision instrumentation.
Compact metal enclosure with integrated high-voltage output cable assembly.
10-Way Input & Control Interface
The unit uses an integrated 10-way Molex friction-lock connector for power, analog programming, telemetry, signal grounds, and interlock functions.
Pin | Signal | Function / Description |
|---|---|---|
P1 | +24VDC_IN | +24 VDC ±10% primary power input; <1 A current ceiling. |
P2 | PWR_GND | Primary return path / power ground for the DC input. |
P3 | EARTH | Low-impedance chassis earth / shield grounding connection. |
P4 | V_PROG_IN | 0 to +10 V analog voltage programming input; Zᵢₙ = 200 kΩ. |
P5 | SIGD_1 | Isolated instrumentation programming feedback signal ground. |
P6 | V_MON_OUT | 0 to +10 V voltage monitor output; ±2% telemetry; Zₒᵤₜ = 10 kΩ. |
P7 | I_MON_OUT | 0 to +10 V current monitor output; ±2%, with ±0.1% FS offset specification; Zₒᵤₜ = 10 kΩ. |
P8 | SIGD_2 | Isolated telemetry / logging circuit reference signal ground. |
P9 | INTLK_A | High-speed safety arc / short fault trigger A. |
P10 | INTLK_B | High-speed safety arc / short fault trigger B. |

High-Voltage Output
Output: 0 to +5 kV DC, programmable.
Maximum continuous output current: 2 mA.
HV distribution: 1 m double-shielded, screened coaxial high-insulation cable assembly.
Output protection includes intermittent-arcing suppression and short-circuit-to-ground safe-trip behavior.
Environmental & Mechanical
SN | Parameter | Specification |
|---|---|---|
1 | Operating temperature | 0°C to +40°C |
2 | Storage temperature | −20°C to +60°C |
3 | Humidity | Maximum 80% RH, non-condensing |
4 | Cooling method | Natural convection (fanless) |
5 | Dimensions | 147 × 98 × 47 mm (W × L × H) |
6 | Mass | ≤1.0 kg |
7 | Input/control connector | 10-way Molex friction-lock header |
8 | HV cable | 1 m shielded / screened high-insulation coaxial assembly |
Engineering Note
Environmental limits, cooling requirements, insulation ratings, dielectric withstand, leakage current, EMC compliance, and detailed mechanical mounting-hole geometry are not specified in the supplied QUTE engineering datasheet. They should be added once the corresponding qualification data are finalized.
Performance & System Integration Notes
Topic | Note |
|---|---|
Programming interface | Use a low-noise 0–10 V analog source. The programming input is specified as 0–100% output scaling. |
Monitoring | Voltage and current monitor outputs provide scaled 0 -10 V feedback for external ADC/DAQ/control systems. |
Grounding | Use P3/EARTH for chassis/shield bonding and the specified signal-ground pins for instrumentation references. |
Interlock | INTLK_A and INTLK_B are dedicated safety fault inputs associated with arc/short protection. |
Warm-up | The stated output drift specification applies after a 1-hour warm-up period. |
HV safety | The +5 kV output is hazardous. Enclosure access, cabling, grounding, interlocks, and discharge procedures must be handled by qualified personnel. |
Ordering / Configuration
SN | Parameter | Specification |
|---|---|---|
1 | Product | QE-HVPS-5K2M-P |
2 | Output voltage | 0 to +5 kV DC |
3 | Output current | 0 to 2 mA maximum |
4 | Polarity | +ve |
5 | Control | 0-10 V analog programming |
6 | Monitoring | 0-10 V voltage and current monitor outputs |
7 | Input | +24 VDC |